What was found
STATION 31J - INSPECTION FOUND A .25 INCH CRACK IN FLANGE WHERE NUT PLATE MOUNTS, ON STRINGER 26L IN AFT PIT. THE CRACK WAS STOP DRILLED IAW SRM 51-10-1, PAGE 6A. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-4 AND 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 31J - INSPECTION FOUND A .25 INCH CRACK IN FLANGE WHERE NUT PLATE MOUNTS, ON STRINGER 26L IN AFT PIT. THE CRACK WAS STOP DRILLED IAW SRM 51-10-1, PAGE 6A. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-4 AND 51-30-2. (M)