As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STATION 31J - INSPECTION FOUND CORROSION AT BOTTOM OF FLOOR BEAM AT GILL SUPPORT FRAME ANGLE IN AFT CARGO PIT AT BS 1168, RBL 55. THE CORRODED AREA OF ANGLE WAS CUT OUT. A NEW ANGLE AND DOUBLER ANGLE WERE FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-20-2, AND 51-40-3. (M)