What was found
STATION 31J - INSPECTION FOUND FUSELAGE PANEL SUPPORT CORRODED BELOW ANCHOR NUT AT BS 813, LBL 9 BETWEEN LEFT AND RIGHT HEAT EXCHANGER. THE CORROSION WAS REMOVED IAW SRM 51-10-2, AN 'L' ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-30-2, AND MM 51-20. (M)