SDR CAL960516

Service difficulty report · Power Supply · Doug DC932

Difficulty date
April 17, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N13512
Make and model
Doug DC932
Aircraft serial
48111
Part
Power Supply
Condition
Inoperative
Location
Cabin
Part time
45,328 hours
Stage of operation
IN
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

GSO - THE FORWARD DROP CEILING EMERGENCY POWER SUPPLY SELF TEST ILLUMINATES ALL FLOOR TRACK LIGHTING INSTEAD OF 75 PERCENT OF TRACK LIGHTING. FOUND DEFECTIVE DIODE AT OVERWING EXIT ROW. REPLACED DIODE IAW WDM 33-15-03. CHECKED SYSTEM OPERATION PER DC-9 MM 33-53-0. SYSTEM OPS CHECK GOOD. (M)