What was found
HOU - INSPECTION FOUND A .375 INCH CRACK IN KEEL BEAM INTERNAL ANGLE AT STATION 946, SIX INCHES LEFT OF CENTER LINE. THE AREA WAS REPAIRED IAW SRM 51-30-2 AND 51-30-5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HOU - INSPECTION FOUND A .375 INCH CRACK IN KEEL BEAM INTERNAL ANGLE AT STATION 946, SIX INCHES LEFT OF CENTER LINE. THE AREA WAS REPAIRED IAW SRM 51-30-2 AND 51-30-5. (M)