What was found
GSO - INSPECTION FOUND FOUR EACH ATTACH ANGLES CRACKED AT LT MLG STR 18A SHEAR BEAM. THE CRACKS MEASURED FROM 2 TO 5 INCHES IN LENGTH. THE ANGLES WERE REMOVED AND NEW ANGLES WERE FABRICATED AND INSTALLED IAW ECRA 5310-03254. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND FOUR EACH ATTACH ANGLES CRACKED AT LT MLG STR 18A SHEAR BEAM. THE CRACKS MEASURED FROM 2 TO 5 INCHES IN LENGTH. THE ANGLES WERE REMOVED AND NEW ANGLES WERE FABRICATED AND INSTALLED IAW ECRA 5310-03254. (X)