What was found
INSPECTION FOUND CORROSION AROUND FASTENER HOLE AT RT LOWER CORNER OF RT AFT EMERGENCY EXIT DOOR. THE CORROSION WAS REMOVED IAW SRM 51-10-3 AND 51-30-2. A BRACKET WAS INSTALLED IAW SRM 51-10-4 AND 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND CORROSION AROUND FASTENER HOLE AT RT LOWER CORNER OF RT AFT EMERGENCY EXIT DOOR. THE CORROSION WAS REMOVED IAW SRM 51-10-3 AND 51-30-2. A BRACKET WAS INSTALLED IAW SRM 51-10-4 AND 51-30-1.