What was found
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT GALLEY, STA 760-890, LBL 45 AND STA 780-880, RBL 45. NEW FLOOR SUPPORTS WERE INSTALLED IAW SRM 53-13-01, 53-70-00, FIGURE 13, AND 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.