What was found
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT AT STA 575, RBL 65. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-60-01, 51-21-01, AND 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT AT STA 575, RBL 65. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-60-01, 51-21-01, AND 51-31-01.