What was found
INSPECTION FOUND A 3 INCH CRACK IN R-1 DOOR THRESHOLD FLOOR SUPPORT WEB AT FORWARD EDGE OF DOOR CUTOUT. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS INSTALLED IAW SRM 53-01, FIGURE 2, 51-10-3, 51-30-2, AND 51-30-6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 3 INCH CRACK IN R-1 DOOR THRESHOLD FLOOR SUPPORT WEB AT FORWARD EDGE OF DOOR CUTOUT. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS INSTALLED IAW SRM 53-01, FIGURE 2, 51-10-3, 51-30-2, AND 51-30-6.