What was found
INSPECTION FOUND A 2 INCH CRACK IN VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE AT RT AFT END, STA 1275. FASTENERS WERE REMOVED AND THE CRACKED AREA WAS CUT OUT IAW SRM 51-30-5 AND 53-05, FIGURE 23. AN ANGLE REPAIR WAS INSTALLED IAW SRM 53-05, FIGURE 23, 51-10-3, 51-10-4, 51-10-3, AND 51-30-5, FIGURE 23.