What was found
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 200, LBL 4 - RBL 4 AND AT STA 224, RBL 14. THE FLOOR SUPPORTS WERE REMOVED AND NEW FLOOR SUPPORTS WERE INSTALLED IAW SRM 51-03-5, 51-30-5, 53-14-1, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT STA 200, LBL 4 - RBL 4 AND AT STA 224, RBL 14. THE FLOOR SUPPORTS WERE REMOVED AND NEW FLOOR SUPPORTS WERE INSTALLED IAW SRM 51-03-5, 51-30-5, 53-14-1, AND 51-30-2.