What was found
INSPECTION FOUND LT CARGO TIE DOWN TRACK CORRODED AT STA 522 - 788, LONGERON 27L. THE CORROSION WAS REMOVED AND FOUND WITHIN LIMITS AT STA 522 - 655 AND STA 684 - 788. THESE SECTIONS WERE ALODINED AND PRIMED IAW SRM 51-10-3 AND 53-01. THE SECTION FROM STA 655 - 684 WAS OUT OF LIMITS. THIS SECTION WAS REMOVED AND A NEW SECTION OF TRACK WAS INSTALLED IAW SRM 53-01, FIGURE 1, 51-10-4, AND 51-10-3.