What was found
INSPECTION FOUND RT ELEVATOR ANTI-FLOAT TAB DELAMINATED AT O/B UPPER SIDE. THE DELAMINATED AREA WAS CUT OUT IAW SRM 51-70-2. REPAIR CORE AND WEDGE DOUBLER WERE BONDED IAW SRM 51-70-2. DEFLASHED BOND AND APPLIED FILLET SEAL IAW SRM 51-70-2. BALANCED TAB IAW MD80 SRM 55-20-2.