INSPECTION FOUND A 6 INCH CRACK IN SUBFLOOR WEB AT STA 1170, LBL 56. THE CRACKED AREA OF WEB WAS REMOVED AND FILLER AND DOUBLER WERE INSTALLED IAW SRM 53-01, FIGURE 4, 53-14-3, FIGURE 12, AND 51-30-2.