What was found
INSPECTION FOUND A 2 INCH CRACK IN BOTH THE AFT AND FWD LOWER DOOR STOPS ON FWD CARGO DOOR. THE CRACKS WERE STOP DRILLED IAW SRM 52-03. DOUBLERS WERE INSTALLED AT EACH LOCATION IAW SRM 51-10-4, 51-10-3, 51-30-2, 51-30-7, 52-03, FIGURE 8, AND ECRA 5230-01554.