What was found
SUB FLOOR PUNCTURED APPROX FS 170 - RBL 10. CUT OUT DAMAGED AREA IAW SRM 53-01 FIG 1. FABRICATED DOUBLER IAW SRM 53-14-1 FIG 4. LOCATED AND DRILLED IAW SRM 51-30-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SUB FLOOR PUNCTURED APPROX FS 170 - RBL 10. CUT OUT DAMAGED AREA IAW SRM 53-01 FIG 1. FABRICATED DOUBLER IAW SRM 53-14-1 FIG 4. LOCATED AND DRILLED IAW SRM 51-30-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-2.