INSPECTION FOUND FLOOR SUPPORT BEAM CAPPING STRIP AFT OF LAVS E AND F AT STA Y = 1887, X = 5R-24R CORRODED. A NEW SECTION WAS INSTALLED IAW GMM 10-900-01 AND SRM 53-16-01.