What was found
INSPECTION FOUND MID CARGO LT TIE DOWN TRACK CORRODED AT FS 522 - 798. THE CORROSION WAS REMOVED IAW SRM 51-10-3. THE TRACK WAS TREATED AND PRIMED FROM FS 522 - 617 AND FROM 700 - 798. FS 617 - 700 WAS FOUND OUT OF LIMITS. A REPAIR TRACK WAS INSTALLED FROM FS 617 - 700 USING REPAIR SPLICES IAW SRM 51-10-4, 53-05, FIGURE 46, 51-10-3, 51-30-2, AND 51-30-1.