What was found
INSPECTION FOUND LONGITUDINAL SUPPORT BEAM AFT OF GALLEY G-1 CORRODED AT STA Y = 412-487, X = 24L. A NEW SECTION OF SUPPORT BEAM WAS INSTALLED IAW GMM 10-900-01 AND SRM 53-11-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND LONGITUDINAL SUPPORT BEAM AFT OF GALLEY G-1 CORRODED AT STA Y = 412-487, X = 24L. A NEW SECTION OF SUPPORT BEAM WAS INSTALLED IAW GMM 10-900-01 AND SRM 53-11-01.