What was found
INSPECTION FOUND AFT EMERGENCY EXIT RAMP UPPER LEFT RAIL CHANNEL EDGE TORN AT FS 1474 WITH A LARGE DENT 20 INCHES AFT. THE TORN EDGE WAS BLENDED OUT AND REPAIR DOUBLERS AND ANGLES WERE INSTALLED IAW SRM 53-01, FIGURE 1 & 2, 51-10-4, 51-10-3, AND 51-30-2. THE DENT WAS REFORMED IAW SRM 51-10-2.