What was found
INSPECTION FOUND LT CABIN FLOORBEAM CORRODED AROUND NUT CLIP HOLES. A REPAIR WAS INSTALLED IAW SRM 53-05, FIGURE 20A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND LT CABIN FLOORBEAM CORRODED AROUND NUT CLIP HOLES. A REPAIR WAS INSTALLED IAW SRM 53-05, FIGURE 20A.