What was found
INSPECTION FOUND A 4 INCH CRACK IN FLOOR SUPPORT ANGLE IN AFT PIT AT STA 1003, LBL 12. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS INSTALLED IAW SRM 51-10-4, 53-01, FIGURE 2, 53-14-3, FIGURE 5, 51-10-3, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 4 INCH CRACK IN FLOOR SUPPORT ANGLE IN AFT PIT AT STA 1003, LBL 12. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS INSTALLED IAW SRM 51-10-4, 53-01, FIGURE 2, 53-14-3, FIGURE 5, 51-10-3, AND 51-30-2.