What was found
INSPECTION FOUND FLOOR SUPPORTS DELAMINATED AT STA 540, RBL 24-RBL 48 AND AT LBL 24-LBL 48. A TWO INCH CRACK WAS FOUND IN EACH FLOOR SUPPORT AT STA 540, RBL 1 AND LBL 1. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.