What was found
INSPECTION FOUND INTERCOSTAL AND AFT ATTACH ANGLE IN MID PIT CORRODED BETWEEN STA 709 AND 788, L27R TO L28R. THE INTERCOSTAL AND ANGLE WERE REMOVED AND A NEW INTERCOSTAL AND ANGLE WERE INSTALLED IAW SRM 51-30-2, 51-30-3, 51-30-4, AND 51-30-5.