What was found
INSPECTION FOUND LAV C I/B FLOOR SUPPORT CORRODED AT STA Y = 840-899, X = 60L. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-13-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND LAV C I/B FLOOR SUPPORT CORRODED AT STA Y = 840-899, X = 60L. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-13-01.