What was found
INSPECTION FOUND AFT LT LAV FLOORBEAM CORRODED AT STA 1322, LBL 41. THE CORROSION WAS TRIMMED OUT AND A DOUBLER, REPAIR STRIP, AND SHIM WERE INSTALLED IAW SRM 53-05, FIGURE 20A, 51-30-2, AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND AFT LT LAV FLOORBEAM CORRODED AT STA 1322, LBL 41. THE CORROSION WAS TRIMMED OUT AND A DOUBLER, REPAIR STRIP, AND SHIM WERE INSTALLED IAW SRM 53-05, FIGURE 20A, 51-30-2, AND 51-30-5.