What was found
INSPECTION FOUND A .5 INCH CRACK IN FLOOR SUPPORT WEB AT STA 344 - 360, BL 0. THE WEB WAS REMOVED AND A NEW WEB WAS INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN FLOOR SUPPORT WEB AT STA 344 - 360, BL 0. THE WEB WAS REMOVED AND A NEW WEB WAS INSTALLED IAW SRM 51-40-02.