What was found
INSPECTION FOUND GALLEY G7 O/B FLOOR SUPPORT BEAM CORRODED AT STA Y = 1902-2007, X = 48L. THE FLOOR SUPPORT BEAM WAS REMOVED AND A NEW SECTION WAS INSTALLED IAW GMM 10-900-01, SRM 53-16-01, AND ECRA 5100-01844.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND GALLEY G7 O/B FLOOR SUPPORT BEAM CORRODED AT STA Y = 1902-2007, X = 48L. THE FLOOR SUPPORT BEAM WAS REMOVED AND A NEW SECTION WAS INSTALLED IAW GMM 10-900-01, SRM 53-16-01, AND ECRA 5100-01844.