What was found
INSPECTION FOUND AFT CARGO PIT DOOR JAMB BEAM CORRODED. A NEW BEAM WAS INSTALLED IAW SRM 51-30-4 AND 51-30-5. TWO DOOR STOP BRACKETS AND 3 SCUFF PLATE STRAPS WERE INSTALLED IAW SRM 51-30-5 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND AFT CARGO PIT DOOR JAMB BEAM CORRODED. A NEW BEAM WAS INSTALLED IAW SRM 51-30-4 AND 51-30-5. TWO DOOR STOP BRACKETS AND 3 SCUFF PLATE STRAPS WERE INSTALLED IAW SRM 51-30-5 AND 51-30-2.