What was found
INSPECTION FOUND AFT RT LAV FLOOR SUPPORT BEAM CORRODED AROUND FASTENER HOLES AT STA 998-1016, RBL 36. THE FLOOR SUPPORT BEAM WAS REMOVED AND REPLACED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND AFT RT LAV FLOOR SUPPORT BEAM CORRODED AROUND FASTENER HOLES AT STA 998-1016, RBL 36. THE FLOOR SUPPORT BEAM WAS REMOVED AND REPLACED IAW SRM 51-40-02.