What was found
INSPECTION FOUND DIAGONAL FLOOR SUPPORT CORRODED AROUND FASTENER HOLES AT STA 986-1016 IN RT AFT LAV AREA. THE DIAGONAL FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND DIAGONAL FLOOR SUPPORT CORRODED AROUND FASTENER HOLES AT STA 986-1016 IN RT AFT LAV AREA. THE DIAGONAL FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-40-02.