INSPECTION FOUND FLOOR SUPPORT CORRODED AT SCREW HOLES AT STA 1006-1016, LBL 36. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT CORRODED AT SCREW HOLES AT STA 1006-1016, LBL 36. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-40-02.