What was found
INSPECTION FOUND UPPER SURFACE OF FLOORBEAM CORRODED AT STA 986.5. THE CORRODED SECTION OF FLOORBEAM T-CAP WAS REMOVED AND A NEW SECTION WAS INSTALLED USING REPAIR STRAP AND ANGLES IAW SRM 51-40-00 AND ECRA 5310-03851.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND UPPER SURFACE OF FLOORBEAM CORRODED AT STA 986.5. THE CORRODED SECTION OF FLOORBEAM T-CAP WAS REMOVED AND A NEW SECTION WAS INSTALLED USING REPAIR STRAP AND ANGLES IAW SRM 51-40-00 AND ECRA 5310-03851.