As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION FOUND RT MLG SUPPORT BEAM HAD LOOSE BEARING HOUSING AND FROZEN BEARING AT MOUNT FITTING. REMOVED NR 5 FLAP TRACK WITH TRANSMISSION, REMOVED FITTING AND INSTALLED NEW BEARING. REINSTALLED NR 5 FLAP TRACK WITH TRANSMISSION. MAINTENANCE WAS PERFORMED IAW MM 27-51-71, PAGE 410-411 AND ECRA 5750-03524.