What was found
INSPECTION FOUND FORWARD END OF FLOOR PAN CORRODED AT STA 986.5-1016, RBL 36-48. THE CORRODED FLOOR PAN WEB WAS REMOVED AND A NEW FLOOR PAN WEB WAS INSTALLED IAW SRM 51-10-2, 51-40-01, AND DRAWING 65C32677.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FORWARD END OF FLOOR PAN CORRODED AT STA 986.5-1016, RBL 36-48. THE CORRODED FLOOR PAN WEB WAS REMOVED AND A NEW FLOOR PAN WEB WAS INSTALLED IAW SRM 51-10-2, 51-40-01, AND DRAWING 65C32677.