INSPECTION FOUND FLOORBEAM CORRODED ON UPPER SURFACE AROUND SCREW HOLES AT STA 967, RBL 27, LBL 6, AND LBL 27. REPAIR STRAPS AND SHIMS WERE INSTALLED IAW SRM 53-00-51, FIGURE 203, 51-20-01, AND 51-30-01.