What was found
INSPECTION FOUND SHEAR CLEAT IN CENTER CARGO BILGE CORRODED AT STA 1801 BETWEEN LONGERON 49L AND 49R. THE SHEAR CLEAT WAS REMOVED AND A NEW SHEAR CLEAT WAS INSTALLED IAW SRM 51-30-01 AND GMM 10-900-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND SHEAR CLEAT IN CENTER CARGO BILGE CORRODED AT STA 1801 BETWEEN LONGERON 49L AND 49R. THE SHEAR CLEAT WAS REMOVED AND A NEW SHEAR CLEAT WAS INSTALLED IAW SRM 51-30-01 AND GMM 10-900-01.