What was found
INSPECTION FOUND A 6 INCH CRACK IN CENTER CARGO FLOOR SUPPORT FLANGE AT STA 1601, X = 18R. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-30-1 AND GMM 10-900-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 6 INCH CRACK IN CENTER CARGO FLOOR SUPPORT FLANGE AT STA 1601, X = 18R. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-30-1 AND GMM 10-900-01.