INSPECTION FOUND BOTH RT LANDING GEAR DOOR TO STABILIZER BEAM BOLTS PITTED AND ONE BOLT HAD A .25 INCH CRACK. NEW BOLTS, WASHERS, AND NUTS WERE INSTALLED IAW MM 32-00-00.