What was found
INSPECTION FOUND FIVE INTERCOSTALS CORRODED INSIDE TORQUE BOX AT AFT CARGO PIT AREA, FS 1165 - 1203. THE INTERCOSTALS WERE REMOVED AND NEW INTERCOSTALS WERE INSTALLED IAW SRM 51-10-4, 51-10-3, 51-30-1, AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FIVE INTERCOSTALS CORRODED INSIDE TORQUE BOX AT AFT CARGO PIT AREA, FS 1165 - 1203. THE INTERCOSTALS WERE REMOVED AND NEW INTERCOSTALS WERE INSTALLED IAW SRM 51-10-4, 51-10-3, 51-30-1, AND 51-30-5.