What was found
INSPECTION FOUND FORWARD PIT(TORQUE BOX) FWD CLOSEOUT AT LIGHTENING HOLE(SLANT PANEL) CORRODED AT AND AROUND FASTENER HOLES AT FS 336. REMOVED FITTING, WEB, AND ANGLE IAW SRM 51-30-1 AND 51-30-2. A NEW WEB AND ANGLE WERE INSTALLED IAW SRM 51-10-4, 51-10-3, AND 51-30-2. INSTALLED FITTING IAW SRM 51-30-1.