What was found
INSPECTION FOUND CABIN L/H I/B FLOOR PANEL DELAMINATED AT FS 1079-1155 AND R/H I/B FLOOR PANEL WAS DELAMINATED AT FS 927-1003. NEW FLOOR PANELS WERE INSTALLED IAW ECRA 5320-01265.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND CABIN L/H I/B FLOOR PANEL DELAMINATED AT FS 1079-1155 AND R/H I/B FLOOR PANEL WAS DELAMINATED AT FS 927-1003. NEW FLOOR PANELS WERE INSTALLED IAW ECRA 5320-01265.