What was found
INSPECTION FOUND AFT CARGO DOOR JAMB SILL CORRODED AT STA 1155-1212. A REPAIR WAS INSTALLED IAW SRM 53-05, FIGURE 63.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND AFT CARGO DOOR JAMB SILL CORRODED AT STA 1155-1212. A REPAIR WAS INSTALLED IAW SRM 53-05, FIGURE 63.