What was found
INSPECTION FOUND ONE EACH 3/4" CRACK IN GUSSET ATTACH BRACKETS AT RIVET ATTACH ON L/H AND R/H SIDE OF NWW FWD WALL. A NEW STIFFENER WAS INSTALLED AT EACH LOCATION IAW SRM 53-14-1, FIGURE 4 AND 51-30-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND ONE EACH 3/4" CRACK IN GUSSET ATTACH BRACKETS AT RIVET ATTACH ON L/H AND R/H SIDE OF NWW FWD WALL. A NEW STIFFENER WAS INSTALLED AT EACH LOCATION IAW SRM 53-14-1, FIGURE 4 AND 51-30-0.