What was found
CABIN LAVATORY WALL FLOOR SUPPORT ANGLE CORRODED AT STATION 995 LBL 13 - 42. REMOVED AND REPLACED L-ANGLE PER SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN LAVATORY WALL FLOOR SUPPORT ANGLE CORRODED AT STATION 995 LBL 13 - 42. REMOVED AND REPLACED L-ANGLE PER SRM 51-10-02.