What was found
INSPECTION FOUND A 1/2" CRACK AT HOLE IN SPAR CAP AT R/H WING MLG BEAM ATTACH FITTING. REPAIRED IAW ECRA 5740-02000. THE ITEM WAS PLACED ON DIP TO PERFORM AN HFEC INSPECTION ON THE R/H WING REAR SPAR AT MLG BEAM ATTACH FITTING AT THE LOCATION REFERENCED IN ECRA 5740-02000. THE INSPECTION IS TO BE PERFORMED AT "C" CHECK INTERVALS OR AT 4500 FLIGHT CYCLES AND ANY CRACK FOUND MUST BE REPAIRED.