What was found
INSPECTION FOUND THE L/H AND R/H MLG(WALKING BEAM) O/B ATTACH FITTING BUSHINGS CORRODED. THE CORROSION WAS REMOVED AND A NEW BUSHING WAS INSTALLED AT EACH LOCATION IAW ECRA 5741-01017.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND THE L/H AND R/H MLG(WALKING BEAM) O/B ATTACH FITTING BUSHINGS CORRODED. THE CORROSION WAS REMOVED AND A NEW BUSHING WAS INSTALLED AT EACH LOCATION IAW ECRA 5741-01017.