What was found
INSPECTION FOUND A 3" CRACK IN WEB AT R/H SIDEWALL FLOOR BETWEEN STA 559 AND 578. THE WEB WAS REMOVED AND A NEW WEB WAS INSTALLED IAW SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 3" CRACK IN WEB AT R/H SIDEWALL FLOOR BETWEEN STA 559 AND 578. THE WEB WAS REMOVED AND A NEW WEB WAS INSTALLED IAW SRM 51-10-02.