What was found
INSPECTION FOUND FLOOR SUPPORTS AT STA 344-360 BL 0 AND LBL 10 CRACKED. THE CRACKS WERE .5 INCH AND 4 INCH. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02, 51-40-02, AND DRAWING 65C33970-53.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORTS AT STA 344-360 BL 0 AND LBL 10 CRACKED. THE CRACKS WERE .5 INCH AND 4 INCH. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-10-02, 51-40-02, AND DRAWING 65C33970-53.